Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Trauma ; (12): 1028-1032, 2014.
Article in Chinese | WPRIM | ID: wpr-469537

ABSTRACT

Objective To evaluate the application of three-dimensional measurement and computer-aided navigation system in treatment of orbitozygomatic complex fiacture.Methods Pre-and post-operative three-dimensional measurements were taken by Mimics software to locate the zygomatic bones of 15 patients with orbitozygomatic complex ftacture to determine distance of optical foramen to zygomaticotemporal suture (On-Zm)/ zygomaticofrontal suture (On-Or)/zygomaticomaxillary suture (OnTz),horizontal angle of zygomatic arch,horizontal angle of the zygomatic process,and inferior angel of the frontal process of zygomatic bone.Preoperative design and simulation,intraoperative real time navigation and postoperative evaluation were applied using computer assisted navigation system.Results OnTz,On-Or,and On-Zm was (48.6-±4.5)mm,(42.5±2.2)mm,and (47.5±3.2)mmin the unaffected side,but was (50.4 ± 2.2) mm,(37.2 ± 1.0) mm,and (53.4 ± 3.6) mm in the affected side before operation (P < 0.05).Whereas On-Tz,On-Or,and On-Zm improved to (46.4 ± 3.7) mm,(41.2 ± 1.8) mm,and (46.4 ± 2.5) mm in the affected side after operation,similar with the values in the unaffected side (P < 0.05).Horizontal angle of zygomatic arch,horizontal angle of the zygomatic process,and inferior angel of the frontal process of zygomatic bone was (144.7 ±4.1)°,(132.5 ± 2.3)°,and (112.0 ± 3.4)° in the affected side,with significant differences from (150.3 ± 8.0)°,(141.1 ±4.2)°,and (114.9 ±5.1)° in the affected side before operation (P <0.05),but they were improved to almost the normal values (144.6 ± 4.1) o,(132.8 ± 2.0) °,and (111.9 ± 3.6) ° after operation.Satisfactory surgical outcomes,such as three dimensional symmetry and recovery of normal mouth-openingand occlusion,had been achieved.Conclusions Three-dimensional measurement is a quantitative study on the spatial displacement of orbitozygomatic complex.Combined with computer-assisted navigation system with preoperative design and simulation,intraoperative real time navigation and postoperative evaluation,three-dimensional measurement attains the overall management of orbitozygomatic complex fracture.

2.
Journal of Practical Stomatology ; (6): 845-849, 2009.
Article in Chinese | WPRIM | ID: wpr-405590

ABSTRACT

Objective: To evaluate the result of distraction osteogenesis in patients with pretnaxillary deficiency using a self-made tooth-borne distraction device. Methods: A self-made tooth-bome distraction device was used for advancement of the maxillary anterior segment in 28 patients. Results; 26 cases were corrected satisfactorily and have no any complications. In 2 cases the distraction device did not work during distraction. Conclusion: This device can improve the soft tissue profile and correct the space deficiency of the maxilla.

SELECTION OF CITATIONS
SEARCH DETAIL